Laminar
flow sampling booth with side-mounted pharma high-speed doors and a clean
ropom as anterroom with integrated personnel lock
|
DESCRIPTION
The heart of the laminar flow sampling booth is an LF recirculation air
booth providing product and personal protection. These conditions are
achieved by targeted air ro"ting. A clean and low-turbulence air
flow (Laminar Flow) vertically flows into the workspace of the sampling
booth cabin and is exhausted back close to the bottom - air-borne substances
are collected in a controlled manner. The integrated ahr exhaust system
which generates a low negative pressure in the workspace of the sampling
booth, perrnanently protects the ambient space against contar"inations
(cross contarninationJ. Loading and unloading of the sampling booth with
the material to be sampled can be effected via the sidemounted pharrna
high-speed doors manually through an automatic conveyor system.
For the Installation of the sampling boofh in a nonclassified space (e.g.,
incoming goods store), it is possible to connect a turhulence-vented clean
room (anteroom) with integrated personnel lock.
A connection of the sampling booth to an external supply or exharrst
air system is not required.
|